Afc also offers parking deck lot cable pvc jacketed mc cable which is mc cable with galvanized steel armor with a pvc jacket.
Pvc coated mc cable nec.
Sustainability careers contact us legal disclaimer.
Also used in continuous runs to outdoor or underground swimming pool motors pumps and related equipment per nec 680 fished exposed or concealed cable trays direct sunlight and hazardous locations up to class i ii div.
Sep 13 2007 2 al long as it s identified for the use.
Southwire patents southwire canada california supply chain act recalls.
Jacketed metal clad cable and teck cable metal clad cable type mc ref.
I checked the nec thinking that i would find something prohibiting such use.
Armorlite type mc pvc jacketed neutral per phase cable view pdf.
2 and class iii div.
Previous wording did not require the corrosion resistant jacket as a prerequisite to use the 3 conditions.
This cable is great for signal circuits in wet dirty or oily locations can be buried directly in earth or concrete surface mounted or trenched for use in parking deck or parking lot applications golf courses docks swimming pool motors and many more.
I would like to use pvc coated mc cable imbedded in concrete in a 2 story residential application for branch circuits for lighting and power.
However in the 2002 nec type mc cable has been relocated into article 330 until you become familiar with the new location in the nec it may take some searching to find it.
The most common is the pvc coated sunlight resistant direct burial listed mc cable in the image.
I never seen or should i say i never noticed mc be used outside like this.
This advanced proprietary coating process by nec delivers extraordinary maintenance efficiencies for systems exposed and susceptible to corrosive environments ans problems helping to alleviate costly repairs and downtime.
I noticed an install done today where mc cable was used outside under a canvas awning to supply fluorescent strip fixtures on a store front.
1 2 nec articles 501 502 503 530 galvanized steel armor with pvc jacket.
The revised 2014 code language makes it clear that a corrosion resistant jacket must be present over the cable and then the 3 conditions apply.
Nec article 334 metal clad cable type mc is a factory assembly of one or more conductors each individually insulated and enclosed in a metallic sheath of interlocking tape or a smooth or corrugated tube metal clad cable type mc is rated for use up to 5 000 volts.
Please enter a valid email address.
Are their any nec restriction for this application.